SCI’s latest SPC-2 performance results analysis – chart-of-the-month

SCISPC110822-002 (c) 2011 Silverton Consulting, All Rights Reserved
SCISPC110822-002 (c) 2011 Silverton Consulting, All Rights Reserved

There really wasn’t that many new submissions for the Storage Performance Council SPC-1 or SPC-2 benchmarks this past quarter (just the new Fujitsu DX80S2 SPC-2 run) so we thought it time to roll out a new chart.

The chart above shows a scatter plot of the number of disk drives in a submission vs. the MB/sec attained for the Large Database Query (LDQ) component of an SPC-2 benchmark.

As one who follows this blog and our twitter feed knows we continue to have an ongoing, long running discussion on how I/O benchmarks such as this are mostly just a measure of how much hardware (disks and controllers) are thrown at them.  We added a linear regression line to the above chart to evaluate the validity of that claim and as clearly shown above, disk drive count is NOT highly correlated with SPC-2 performance.

We necessarily exclude from this analysis any system results that used NAND based caching or SSD devices so as to focus specifically on disk drive count relevance.   There are not a lot of these in SPC-2 results but there are enough to make this look even worse.

We chose to only display the LDQ segment of the SPC-2 benchmark because it has the best correlation or highest R**2 at 0.41 between workload and disk count. The aggregate MBPS as well as the other components of the SPC-2 benchmark include video on demand (VOD) and large file processing (LFP) both of which had R**2’s of less than 0.36.

For instance, just look at the vertical centered around 775 disk drives.  There are two systems that show up here, one doing ~ 6000 MBPS and the other doing ~11,500 MBPS – quite a difference.  The fact that these are two different storage architectures from the same vendor is even more informative??

Why is the overall correlation so poor?

One can only speculate but there must be something about system sophistication at work in SPC-2 results.  It’s probably tied to better caching, better data layout on disk, and better IO latency but it’s only an educated guess.  For example,

  • Most of the SPC-2 workload is sequential in nature.  How a storage system detects sequentiality in a seemingly random IO mix is an art form and what a system does armed with that knowledge is probably more of a science.
  • In the old days of big, expensive CKD DASD, sequential data was all laid out in consecutively (barring lacing) around a track and up a cylinder.  These days of zoned FBA disks one can only hope that sequential data resides in laced sectors, along consecutive tracks on the media, minimizing any head seek activity.  Another approach,  popular this last decade, has been to throw more disks at the problem, resulting in many more seeking heads to handle the workload and who care where the data lies.
  • IO latency is another factor.  We have discussed this before (see Storage throughput vs IO response time and why it matters. But one key to systems throughput is how quickly data gets out of cache and into the hands of servers. Of course the other part to this, is how fast does the storage system get the data from sitting on disk into cache.

Systems that do these better will perform better on SPC-2 like benchmarks that focus on raw sequential throughput.

Comments?

—–

The full SPC performance report went out to our newsletter subscribers last month.  A copy of the full report will be up on the dispatches page of our website later next month. However, you can get this information now and subscribe to future newsletters to receive these reports even earlier by just sending us an email or using the signup form above right.

As always, we welcome any suggestions on how to improve our analysis of SPC results or any of our other storage system performance discussions.

 

 

IBM’s 120PB storage system

Susitna Glacier, Alaska by NASA Goddard Photo and Video (cc) (from Flickr)
Susitna Glacier, Alaska by NASA Goddard Photo and Video (cc) (from Flickr)

Talk about big data, Technology Review reported this week that IBM is building a 120PB storage system for some unnamed customer.  Details are sketchy and I cannot seem to find any announcement of this on IBM.com.

Hardware

It appears that the system uses 200K disk drives to support the 120PB of storage.  The disk drives are packed in a new wider rack and are water cooled.  According to the news report the new wider drive trays hold more drives than current drive trays available on the market.

For instance, HP has a hot pluggable, 100 SFF (small form factor 2.5″) disk enclosure that sits in 3U of standard rack space.  200K SFF disks would take up about 154 full racks, not counting the interconnect switching that would be required.  Unclear whether water cooling would increase the density much but I suppose a wider tray with special cooling might get you more drives per floor tile.

There was no mention of interconnect, but today’s drives use either SAS or SATA.  SAS interconnects for 200K drives would require many separate SAS busses. With an SAS expander addressing 255 drives or other expanders, one would need at least 4 SAS busses but this would have ~64K drives per bus and would not perform well.  Something more like 64-128 drives per bus would have much better performer and each drive would need dual pathing, and if we use 100 drives per SAS string, that’s 2000 SAS drive strings or at least 4000 SAS busses (dual port access to the drives).

The report mentioned GPFS as the underlying software which supports three cluster types today:

  • Shared storage cluster – where GPFS front end nodes access shared storage across the backend. This is generally SAN storage system(s).  But the requirements for high density, it doesn’t seem likely that the 120PB storage system uses SAN storage in the backend.
  • Networked based cluster – here the GPFS front end nodes talk over a LAN to a cluster of NSD (network storage director?) servers which can have access to all or some of the storage. My guess is this is what will be used in the 120PB storage system
  • Shared Network based clusters – this looks just like a bunch of NSD servers but provides access across multiple NSD clusters.

Given the above, with ~100 drives per NSD server means another 1U extra per 100 drives or (given HP drive density) 4U per 100 drives for 1000 drives and 10 IO servers per 40U rack, (not counting switching).  At this density it takes ~200 racks for 120PB of raw storage and NSD nodes or 2000 NSD nodes.

Unclear how many GPFS front end nodes would be needed on top of this but even if it were 1 GPFS frontend node for every 5 NSD nodes, we are talking another 400 GPFS frontend nodes and at 1U per server, another 10 racks or so (not counting switching).

If my calculations are correct we are talking over 210 racks with switching thrown in to support the storage.  According to IBM’s discussion on the Storage challenges for petascale systems, it probably provides ~6TB/sec of data transfer which should be easy with 200K disks but may require even more SAS busses (maybe ~10K vs. the 2K discussed above).

Software

IBM GPFS is used behind the scenes in IBM’s commercial SONAS storage system but has been around as a cluster file system designed for HPC environments for over 15 years or more now.

Given this many disk drives something needs to be done about protecting against drive failure.  IBM has been talking about declustered RAID algorithms for their next generation HPC storage system which spreads the parity across more disks and as such, speeds up rebuild time at the cost of reducing effective capacity. There was no mention of effective capacity in the report but this would be a reasonable tradeoff.  A 200K drive storage system should have a drive failure every 10 hours, on average (assuming a 2 million hour MTBF).  Let’s hope they get drive rebuild time down much below that.

The system is expected to hold around a trillion files.  Not sure but even at 1024 bytes of metadata per file, this number of files would chew up ~1PB of metadata storage space.

GPFS provides ILM (information life cycle management, or data placement based on information attributes) using automated policies and supports external storage pools outside the GPFS cluster storage.  ILM within the GPFS cluster supports file placement across different tiers of storage.

All the discussion up to now revolved around homogeneous backend storage but it’s quite possible that multiple storage tiers could also be used.  For example, a high density but slower storage tier could be combined with a low density but faster storage tier to provide a more cost effective storage system.  Although, it’s unclear whether the application (real world modeling) could readily utilize this sort of storage architecture nor whether they would care about system cost.

Nonetheless, presumably an external storage pool would be a useful adjunct to any 120PB storage system for HPC applications.

Can it be done?

Let’s see, 400 GPFS nodes, 2000 NSD nodes, and 200K drives. Seems like the hardware would be readily doable (not sure why they needed watercooling but hopefully they obtained better drive density that way).

Luckily GPFS supports Infiniband which can support 10,000 nodes within a single subnet.  Thus an Infiniband interconnect between the GPFS and NSD nodes could easily support a 2400 node cluster.

The only real question is can a GPFS software system handle 2000 NSD nodes and 400 GPFS nodes with trillions of files over 120PB of raw storage.

As a comparison here are some recent examples of scale out NAS systems:

It would seem that a 20X multiplier times a current Isilon cluster or even a 10X multiple of a currently supported SONAS system would take some software effort to work together, but seems entirely within reason.

On the other hand, Yahoo supports a 4000-node Hadoop cluster and seems to work just fine.  So from a feasability perspective, a 2500 node GPFS-NSD node system seems just a walk in the park for Hadoop.

Of course, IBM Almaden is working on project to support Hadoop over GPFS which might not be optimum for real world modeling but would nonetheless support the node count being talked about here.

——

I wish there was some real technical information on the project out on the web but I could not find any. Much of this is informed conjecture based on current GPFS system and storage hardware capabilities. But hopefully, I haven’t traveled to far astray.

Comments?

 

Shared DAS

Code Name "Thumper" by richardmasoner (cc) (from Flickr)
Code Name "Thumper" by richardmasoner (cc) (from Flickr)

An announcement this week by VMware on their vSphere  5 Virtual Storage Appliance has brought back the concept of shared DAS (see vSphere 5 storage announcements).

Over the years, there have been a few products, such as Seanodes and Condor Storage (may not exist now) that have tried to make a market out of sharing DAS across a cluster of servers.

Arguably, Hadoop HDFS (see Hadoop – part 1), Amazon S3/cloud storage services and most scale out NAS systems all support similar capabilities. Such systems consist of a number of servers with direct attached storage, accessible by other servers or the Internet as one large, contiguous storage/file system address space.

Why share DAS? The simple fact is that DAS is cheap, its capacity is increasing, and it’s ubiquitous.

Shared DAS system capabilities

VMware has limited their DAS virtual storage appliance to a 3 ESX node environment, possibly lot’s of reasons for this.  But there is no such restriction for Seanode Exanode clusters.

On the other hand, VMware has specifically targeted SMB data centers for this facility.  In contrast, Seanodes has focused on both HPC and SMB markets for their shared internal storage which provides support for a virtual SAN on Linux, VMware ESX, and Windows Server operating systems.

Although VMware Virtual Storage Appliance and Seanodes do provide rudimentary SAN storage services, they do not supply advanced capabilities of enterprise storage such as point-in-time copies, replication, data reduction, etc.

But, some of these facilities are available outside their systems. For example, VMware with vSphere 5 will supports a host based replication service and has had for some time now software based snapshots. Also, similar services exist or can be purchased for Windows and presumably Linux.  Also, cloud storage providers have provided a smattering of these capabilities from the start in their offerings.

Performance?

Although distributed DAS storage has the potential for high performance, it seems to me that these systems should perform poorer than an equivalent amount of processing power and storage in a dedicated storage array.  But my biases might be showing.

On the other hand, Hadoop and scale out NAS systems are capable of screaming performance when put together properly.  Recent SPECsfs2008 results for EMC Isilon scale out NAS system have demonstrated very high performance and Hadoops claim to fame is high performance analytics. But you have to throw a lot of nodes at the problem.

—–

In the end, all it takes is software. Virtualizing servers, sharing DAS, and implementing advanced storage features, any of these can be done within software alone.

However, service levels, high availability and fault tolerance requirements have historically necessitated a physical separation between storage and compute services. Nonetheless, if you really need screaming application performance and software based fault tolerance/high availability will suffice, then distributed DAS systems with co-located applications like Hadoop or some scale out NAS systems are the only game in town.

Comments?

SCI May 2011, Latest SPC-1 results IOPS vs. drive count – chart of the month

SCISPC110527-004 (c) 2011 Silverton Consulting, Inc., All Rights Reserved
SCISPC110527-004 (c) 2011 Silverton Consulting, Inc., All Rights Reserved

The above chart is from our May Storage Intelligence newsletter dispatch on system performance and shows the latest Storage Performance Council SPC-1 benchmark results in a scatter plot with IO/sec [or IOPS(tm)] on the vertical axis and number of disk drives on the horizontal axis.  We have tried to remove all results that used NAND flash as a cache or SSDs. Also this displays only results below a $100/GB.

One negative view of benchmarks such as SPC-1 is that published results are almost entirely due to the hardware thrown at it or in this case, the number of disk drives (or SSDs) in the system configuration.  An R**2 of 0.93 shows a pretty good correlation of IOPS performance against disk drive count and would seem to bear this view out, but is an incorrect interpretation of the results.

Just look at the wide variation beyond the 500 disk drive count versus below that where there are only a few outliers with a much narrower variance. As such, we would have to say that at some point (below 500 drives), most storage systems can seem to attain a reasonable rate of IOPS as a function of the number of spindles present, but after that point the relationship starts to break down.  There are certainly storage systems at the over 500 drive level that perform much better than average for their drive configuration and some that perform worse.

For example, consider the triangle formed by the three best performing (IOPS) results on this chart.  The one at 300K IOPS with ~1150 disk drives is from Huawei Symantec and is their 8-node Oceanspace S8100 storage system whereas the other system with similar IOPS performance at ~315K IOPS used ~2050 disk drives and is a 4-node, IBM SVC (5.1) system with DS8700 backend storage.   In contrast, the highest performer on this chart at ~380K IOPS, also had ~2050 disk drives and is a 6-node IBM SVC (5.1) with DS8700 backend storage.

Given the above analysis there seems to be much more to system performance than merely disk drive count, at least at the over 500 disk count level.

—-

The full performance dispatch will be up on our website after the middle of next month but if you are interested in viewing this today, please sign up for our free monthly newsletter (see subscription request, above right) or subscribe by email and we’ll send you the current issue.  If you need a more analysis of SAN storage performance please consider purchasing SCI’s SAN Storage Briefing.

As always, we welcome all constructive suggestions on how to improve any of our storage performance analyses.

Comments?

 

SolidFire supplies scale-out SSD storage for cloud service providers

SolidFire SF3010 node (c) 2011 SolidFire (from their website)
SolidFire SF3010 node (c) 2011 SolidFire (from their website)

I was talking with a local start up called SolidFire the other day with an interesting twist on SSD storage.  They were targeting cloud service providers with a scale-out, cluster based SSD iSCSI storage system.  Apparently a portion of their team had come from Lefthand (now owned by HP) another local storage company and the rest came from Rackspace, a national cloud service provider.

The hardware

Their storage system is a scale-out cluster of storage nodes that can range from 3 to a theoretical maximum of 100 nodes (validated node count ?). Each node comes equipped with 2-2.4GHz, 6-core Intel processors and 10-300GB SSDs for a total of 3TB raw storage per node.  Also they have 8GB of non-volatile DRAM for write buffering and 72GB read cache resident on each node.

The system also uses 2-10GbE links for host to storage IO and inter-cluster communications and support iSCSI LUNs.  There are another 2-1GigE links used for management communications.

SolidFire states that they can sustain 50K IO/sec per node. (This looks conservative from my viewpoint but didn’t state any specific R:W ratio or block size for this performance number.)

The software

They are targeting cloud service providers and as such the management interface was designed from the start as a RESTful API but they also have a web GUI built out of their API.  Cloud service providers will automate whatever they can and having a RESTful API seems like the right choice.

QoS and data reliability

The cluster supports 100K iSCSI LUNs and each LUN can have a QoS SLA associated with it.  According to SolidFire one can specify a minimum/maximum/burst level for IOPS and a maximum or burst level for throughput at a LUN granularity.

With LUN based QoS, one can divide cluster performance into many levels of support for multiple customers of a cloud provider.  Given these unique QoS capabilities it should be relatively easy for cloud providers to support multiple customers on the same storage providing very fine grained multi-tennancy capabilities.

This could potentially lead to system over commitment, but presumably they have some way to ascertain over commitment is near and not allowing this to occur.

Data reliability is supplied through replication across nodes which they call Helix(tm) data protection.  In this way if an SSD or node fails, it’s relatively easy to reconstruct the lost data onto another node’s SSD storage.  Which is probably why the minimum number of nodes per cluster is set at 3.

Storage efficiency

Aside from the QoS capabilities, the other interesting twist from a customer perspective is that they are trying to price an all-SSD storage solution at the $/GB of normal enterprise disk storage. They believe their node with 3TB raw SSD storage supports 12TB of “effective” data storage.

They are able to do this by offering storage efficiency features of enterprise storage using an all SSD configuration. Specifically they provide,

  • Thin provisioned storage – which allows physical storage to be over subscribed and used to support multiple LUNs when space hasn’t completely been written over.
  • Data compression – which searches for underlying redundancy in a chunk of data and compresses it out of the storage.
  • Data deduplication – which searches multiple blocks and multiple LUNs to see what data is duplicated and eliminates duplicative data across blocks and LUNs.
  • Space efficient snapshot and cloning – which allows users to take point-in-time copies which consume little space useful for backups and test-dev requirements.

Tape data compression gets anywhere from 2:1 to 3:1 reduction in storage space for typical data loads. Whether SolidFire’s system can reach these numbers is another question.  However, tape uses hardware compression and the traditional problem with software data compression is that it takes lots of processing power and/or time to perform it well.  As such, SolidFire has configured their node hardware to dedicate a CPU core to each physical disk drive (2-6 core processors for 10 SSDs in a node).

Deduplication savings are somewhat trickier to predict but ultimately depends on the data being stored in a system and the algorithm used to deduplicate it.  For user home directories, typical deduplication levels of 25-40% are readily attainable.  SolidFire stated that their deduplication algorithm is their own patented design and uses a small fixed block approach.

The savings from thin provisioning ultimately depends on how much physical data is actually consumed on a storage LUN but in typical environments can save 10-30% of physical storage by pooling non-written or free storage across all the LUNs configured on a storage system.

Space savings from point-in-time copies like snapshots and clones depends on data change rates and how long it’s been since a copy was made.  But, with space efficient copies and a short period of existence, (used for backups or temporary copies in test-development environments) such copies should take little physical storage.

Whether all of this can create a 4:1 multiplier for raw to effective data storage is another question but they also have a eScanner tool which can estimate savings one can achieve in their data center. Apparently the eScanner can be used by anyone to scan real customer LUNs and it will compute how much SolidFire storage will be required to support the scanned volumes.

—–

There are a few items left on their current road map to be delivered later, namely remote replication or mirroring. But for now this looks to be a pretty complete package of iSCSI storage functionality.

SolidFire is currently signing up customers for Early Access but plan to go GA sometime around the end of the year. No pricing was disclosed at this time.

I was at SNIA’s BoD meeting the other week and stated my belief that SSDs will ultimately lead to the commoditization of storage.  By that I meant that it would be relatively easy to configure enough SSD hardware to create a 100K IO/sec  or 1GB/sec system without having to manage 1000 disk drives.  Lo and behold, SolidFire comes out the next week.  Of course, I said this would happen over the next decade – so I am off by a 9.99 years…

Comments?

EMCWorld day 3 …

Sometime this week EMC announced a new generation of Isilon NearLine storage which now includes HGST 3TB SATA disk drives.  With the new capacity the multi-node (144) Isilon cluster using the 108NL nodes can support 15PB of file data in a single file system.

Some of the booths along the walk to the solutions pavilion highlight EMC innovation winners. Two that caught my interest included:

  • Constellation computing – not quite sure how to define this but it’s distributed computing along with distributed data creation.  The intent is to move the data processing to the source of the data creation and keep the data there.  This might be very useful for applications that have many data sources and where data processing capabilities can be moved out to the nodes where the data was created. Seems highly scaleable but may depend on the ability to carve up the processing to work on the local data. I can see where compression, encryption, indexing and some statistical summarization can be done at the data creation site before it’s sent elsewhere. Sort of like both a sensor mesh with a processing nodes attached to the sensors configured as a sensor-proccessing grid.  Only one thing concerned me, there didn’t seem to be any central repository or control to this computing environment.  Probably what they intended, as the distributed solution is more adaptable and more scaleable than a centrally controlled environment.
  • Developing world healthcare cloud – seemed to be all about delivering healthcare to the bottom of the pyramid.  They won EMC’s social innovation award and are working with a group in Rwanda to try to provide better healthcare to remote villages.  It’s built around OpenMRS as a backend medical record archive hosted on EMC DC powered Iomega NAS storage and uses Google’s OpenDataKit to work with the data on mobile and laptop devices.  They showed a mobile phone which could be used to create, record and retrieve healthcare information (OpenMRS records) remotely and upload it sometime later when in range of a cell tower.  The solution also supports the download of a portion of the medical center’s health record database (e.g., a “cohort” slice, think a village’s healthcare records) onto a laptop, usable offline by a healthcare provider to update and record  patient health changes onsite and remotely.  Pulling all the technology together and delivering this as an application stack usable on mobile and laptop devices with minimal IT sophistication, storage and remote/mobile access are where the challenges lie.

Went to Sanjay’s (EMC’s CIO) keynote on EMC IT’s journey to IT-as-a-Service. As you can imagine it makes extensive use of VMware’s vSphere, vCloud, and vShield capabilities primarily in a private cloud infrastructure but they seem agnostic to a build-it or buy-it approach. EMC is about 75% virtualized today, and are starting to see significant and tangible OpEx and energy savings. They designed their North Carolina data center around the vCloud architecture and now are offering business users self service portals to provision VMs and business services…

Only caught the first section of BJ’s (President of BRS) keynote but he said recent analyst data (think IDC?) said that EMC was the overall leader (>64% market share) in purpose built backup appliances (Data Domain, Disk Library, Avamar data stores, etc.).  Too bad I had to step out but he looked like he was on a roll.

Comments?

EMCWorld day 2

Day 2 saw releases for new VMAX  and VPLEX capabilities hinted at yesterday in Joe’s keynote. Namely,

VMAX announcements

VMAX now supports

  • Native FCoE with 10GbE support now VMAX supports directly FCoE, 10GbE iSCSI and SRDF
  • Enhanced Federated Live Migration supports other multi-pathing software, specifically it now adds MPIO to PowerPath and soon to come more multi-pathing solutions
  • Support for RSA’s external key management (RSA DPM) for their internal VMAX data security/encryption capability.

It was mentioned more than once that the latest Enginuity release 5875 is being adopted at almost 4x the rate of the prior generation code.  The latest release came out earlier this year and provided a number of key enhancements to VMAX capabilities not the least of which was sub-LUN migration across up to 3 storage tiers called FAST VP.

Another item of interest was that FAST VP was driving a lot of flash sales.  It seems its leading to another level of flash adoption. According to EMC they feel that almost 80-90% of customers can get by with 3% of their capacity in flash and still gain all the benefits of flash performance at significantly less cost.

VPLEX announcements

VPLEX announcements included:

  • VPLEX Geo – a new asynchronous VPLEX cluster-to-cluster communications methodology which can have the alternate active VPLEX cluster up to 50msec latency away
  • VPLEX Witness –  a virtual machine which provides adjudication between the two VPLEX clusters just in case the two clusters had some sort of communications breakdown.  Witness can run anywhere with access to both VPLEX clusters and is intended to be outside the two fault domains where the VPLEX clusters reside.
  • VPLEX new hardware – using the latest Intel microprocessors,
  • VPLEX now supports NetApp ALUA storage – the latest generation of NetApp storage.
  • VPLEX now supports thin-to-thin volume migration- previously VPLEX had to re-inflate thinly provisioned volumes but with this release there is no need to re-inflate prior to migration.

VPLEX Geo

The new Geo product in conjuncton with VMware and Hyper V allows for quick migration of VMs across distances that support up to 50msec of latency.  There are some current limitations with respect to specific VMware VM migration types that can be supported but Microsoft Hyper-V Live Migration support is readily available at full 50msec latencies.  Note,  we are not talking about distance here but latency as the limiting factor to how far the VPLEX clusters can be apart.

Recall that VPLEX has three distinct use cases:

  • Infrastructure availability which proides fault tolerance for your storage and system infrastructure
  • Application and data mobility which means that applications can move from data center to data center and still access the same data/LUNs from both sites.  VPLEX maintains cache and storage coherency across the two clusters automatically.
  • Distributed data collaboration which means that data can be shared and accessed across vast distances. I have discussed this extensively in my post on Data-at-a-Distance (DaaD) post, VPLEX surfaces at EMCWorld.

Geo is the third product version for VPLEX, from VPLEX Local that supports within data center virtualization, to Vplex Metro which supports two VPLEX clusters which are up to 10msec latency away which generally is up to metropolitan wide distances apart, and Geo which moves to asynchronous cache coherence technologies. Finally coming sometime later is VPLEX Global which eliminates the restriction of two VPLEX clusters or data centers and can support 3-way or more VPLEX clusters.

Along with Geo, EMC showed some new partnerships such as with SilverPeak, Cienna and others used to reduce bandwidth requirements and cost for their Geo asynchronous solution.  Also announced and at the show were some new VPLEX partnerships with Quantum StorNext and others which addresses DaaD solutions

Other announcements today

  • Cloud tiering appliance – The new appliance is a renewed RainFinity solution which provides policy based migration to and from the cloud for unstructured data. Presumably the user identifies file aging criteria which can be used to trigger cloud migration for Atmos supported cloud storage.  Also the new appliance can support archiving file data to the Data Domain Archiver product.
  • Google enterprise search connector to VNX – Showing a Google search appliance (GSA) to index VNX stored data. Thus bringing enterprise class and scaleable search capabilities for VNX storage.

A bunch of other announcements today at EMCWorld but these seemed most important to me.

Comments?

Initial impressions on Spring SNW/Santa Clara

I heard storage beers last nite was quite the party, sorry I couldn’t make it but I did end up at the HDS customer reception which was standing room only and provided all the food and drink I could consume.

Saw quite a lot of old friends too numerous to mention here but they know who they are.

As for technology on display there was some pretty impressive stuff.

Verident card (c) 2011 Silverton Consulting, Inc.
Verident card (c) 2011 Silverton Consulting, Inc.

Lots of great technology on display there.

Virident tachIOn SSD

One product that caught my eye was from Virident, their tachIOn SSD. I called it a storage subsystem on a board.  I had never talked with them before but they have been around for a while using NOR storage but now are focused on NAND.

Their product is a fully RAIDed storage device using flash aware RAID 5 parity locations, their own wear leveling and other SSD control software and logic with replaceable NAND modules.

Playing with this device I felt like I was swapping drives of the future. Each NAND module stack has a separate controller and supports high parallelism.  Talking with Shridar Subramanian, VP of marketing, he said the product is capable of over 200K IOPS running a fully 70% read:30% write workload at full capacity.

They have a Capacitor backed DRAM buffer which is capable of uploading the memory buffer to NAND after a power failure. It plugs into a PCIe slot and uses less than 25W of power, in capacities of 300-800GB.  It requires a software driver, they currently only support Linux and VMware (a Linux varient) but Windows and other O/Ss are on the way

Other SSDs/NAND storage

Their story was a familair refrain throughout the floor, lots of SSD/NAND technology coming out, in various formfactors.  I saw one system using SSDs from Viking Modular Systems that fit into a DRAM DIMM slot and supported a number of SSDs behind a SAS like controller. Also requiring a SW driver.

(c) 2011 Silverton Consulting, Inc.
(c) 2011 Silverton Consulting, Inc.

Of course TMS, Fusion-IO, Micron, Pliant and others were touting their latest SSD/Nand based technology showing off their latest solutions and technology.   For some reason lots of SSD’s at this show.

Naturally, all the other storage vendors were there Dell, HDS, HP, EMC, NetApp and IBM. IBM was showing off Watson, their new AI engine that won at Jeopardy.

And then there was cloud, …

Cloud was a hot topic as well. Saw one guy in the corner I have talked about before StorSimple which is a cloud gateway provider.  They said they are starting to see some traction in the enterprise. Apparently enterprise are starting to adopt cloud – who knew?

Throw in a few storage caching devices, …

Then of course there was the data caching products which ranged from the relaunched DataRAM XcelASAN to Marvel’s new DragonFLY card.  DragonFLY provides a cache on a PCI-E card which DataRAM is a FC caching appliance, all pretty interesting.

… and what’s organic storage?

And finally, Scality came out of the shadows with what they are calling an organic object storage device.  The product reminded me of Bycast (now with NetApp) and Archivas (now with HDS) in that they had a RAIN architecture, with mirrored data in an object store interface.  I asked them what makes them different and Jerome Lecat, CEO said they are relentlessly focused on performance and claims they can retrieve an object in under 40msec.  My kind of product.  I think they deserve a deeper dive sometime later.

—-

Probably missed a other  vendors but these are my initial impressions.  For some reason I felt right at home swapping NAND drive modules,…